Calibration for Electronics & Semiconductor Manufacturers
QSI calibrates the test equipment, production tools, and inspection instruments that electronics and semiconductor manufacturers rely on, from oscilloscopes and power supplies to soldering irons, ionizers, crimpers, and wire pull testers. Our calibration laboratory in Oxnard, California, is ISO/IEC 17025 accredited. Ship your equipment to us from anywhere in the U.S., or schedule on-site calibration in Ventura County, Santa Barbara County, the Santa Clarita Valley, and Los Angeles.
Electronics Equipment We Calibrate
Bench and test instruments
Multimeters, oscilloscopes up to 1.1 GHz, power supplies, function and waveform generators, logic analyzers, and data acquisition units.
Related: Electrical calibration
RF and microwave test equipment
Spectrum analyzers, network analyzers, signal generators, RF power meters and sensors, and attenuators.
Related: RF & microwave calibration
Frequency counters
Frequency, microwave, and linear counters used to verify oscillators and timing.
Related: Time & frequency calibration
Production and ESD control equipment
Soldering irons, ionization fans, and the humidity indicators and data loggers used to monitor production areas.
Related: Temperature & humidity calibration · Electrical calibration
Assembly tools
Torque drivers and small preset torque wrenches for RF connectors, crimpers and crimp dies, and wire pull testers.
Related: Torque · Dimensional · Force
Safety testers
AC/DC and high-voltage hipot testers, corona testers, and megohmmeters.
Related: Electrical calibration
Inspection tools
Calipers, micrometers, height gages, optical comparators, and pin gages.
Related: Dimensional calibration
Environmental test equipment
Environmental chambers and ovens used for thermal cycling, burn-in, and qualification testing.
Related: Temperature calibration
Production Tools Are Easy to Overlook
Bench instruments usually make it onto the calibration schedule. Production tools often don’t. A soldering iron that runs cold, an ionizer that no longer neutralizes charge quickly, or a pull tester that reads high won’t stop your line. Instead, they quietly let weak joints, ESD damage, and bad crimps through. Calibrating production and ESD equipment alongside your test instruments closes that gap.
Serving Electronics Manufacturers Across the Region
From defense electronics in Ventura County to contract manufacturers in the San Fernando Valley and tech companies in Santa Barbara, QSI supports electronics work across the region, along with customers nationwide through mail-in calibration.
Calibration That Supports Your Quality Standards
Electronics manufacturers answer to a stack of standards, and nearly all of them come back to measurement:
-
ISO 9001 and AS9100 require that measuring equipment be calibrated and traceable, with records to prove it.
-
IPC J-STD-001 soldering work depends on soldering irons that actually reach their set temperature.
-
IPC/WHMA-A-620 sets pull-force requirements for crimped connections, which makes wire pull tester accuracy essential.
-
ANSI/ESD S20.20 ESD control programs call for periodic verification of ionizers and other ESD control equipment.
Every QSI calibration includes a certificate documenting your equipment’s results, so your records are ready when an auditor or customer asks.
Frequently Asked Questions
-
What equipment do electronics manufacturers need calibrated?
Most electronics manufacturers calibrate their bench instruments (multimeters, oscilloscopes, power supplies, and generators), production tools (soldering irons, torque drivers, crimpers, and wire pull testers), safety testers such as hipot testers, inspection tools such as calipers and micrometers, and environmental monitoring equipment such as humidity indicators and data loggers. QSI calibrates all of these.
-
Do ionizers need to be calibrated?
Yes. Ionizers drift as their emitter points wear and collect contamination, which affects both how quickly they neutralize charge and how balanced their output is. ESD control programs such as ANSI/ESD S20.20 call for periodic verification of ionizers, and QSI calibrates ionization fans as part of our electrical calibration services.
-
Do soldering irons need calibration?
Yes. A soldering iron’s actual tip temperature can drift from its set point as tips wear and heating elements age. Too cool and joints may not form properly; too hot and components or boards can be damaged. Regular calibration verifies tip temperature.
-
Can I mail in electronic test equipment for calibration?
Yes. QSI accepts mail-in calibration from anywhere in the United States. Ship your equipment to our Oxnard, California lab, and we’ll return it with your calibration certificate.
-
Is QSI an accredited calibration lab?
Yes. QSI is an ISO/IEC 17025 accredited calibration laboratory, accredited by ANAB (certificate AC-3452). You can view our full scope of accreditation.
Request a Calibration Quote from QSI
-
ISO/IEC 17025 accredited calibration laboratory
-
Compliant certificates with traceable data, ready for your next audit.
-
Send us your equipment list for a clear, itemized quote
-
Nationwide mail-in calibration, or on-site service across Ventura County and surrounding counties